Patton electronic Network Router 07MSN5200 QS User Manual

SmartNode™ Model 5200  
Enterprise Session Border Router  
Quick Start Guide  
ImportantThis is a Class A device and is intended for use in a light industrial (commer-  
cial) environment only. It is not intended nor approved for use in a heavy industrial or resi-  
dential environment.  
This device is approved for connection to the public ISDN telecommunication network, over BRI/S0-  
ISDN interfaces.  
Sales Office: +1 (301) 975-1000  
Part Number: 07MSN5200-QS, Rev. A  
Revised: April 21, 2010  
Technical Support: +1 (301) 975-1007  
 
Electrostatic Discharge (ESD) can damage equipment and impair electrical  
circuitry. It occurs when electronic printed circuit cards are improperly  
handled and can result in complete or intermittent failures. Do the follow-  
ing to prevent ESD:  
CAUTION  
• Always follow ESD prevention procedures when removing and replac-  
ing cards.  
• Wear an ESD-preventive wrist strap, ensuring that it makes good  
skin contact. Connect the clip to an unpainted surface of the chassis  
frame to safely channel unwanted ESD voltages to ground.  
• To properly guard against ESD damage and shocks, the wrist strap  
and cord must operate effectively. If no wrist strap is available,  
ground yourself by touching the metal part of the chassis.  
1.0 Power up the SmartNode  
The interconnecting cables shall be acceptable for external use and shall be rated for  
the proper application with respect to voltage, current, anticipated temperature, flam-  
mability, and mechanical serviceability.  
CAUTION  
1. Connect the SmartNode to a power source using the included power supply and cable.  
2. When the Power LED stops blinking and remains lit, the SmartNode is ready to configure.  
2.0 Set your PC to DHCP  
The interconnecting cables shall be acceptable for external use and shall be rated for  
the proper application with respect to voltage, current, anticipated temperature, flam-  
mability, and mechanical serviceability.  
CAUTION  
This guide will allow you to quickly access the configuration interface of a SmartNode and give an overview of  
the different elements you can or need to configure. For detailed information on all configuration parameters  
refer to the SmartWare software configuration guide.  
The SmartNode has a built in DHCP Server which allows an automatic IP connection with a connected PC. To pre-  
pare the connection you need to configure the PC to use DHCP. The following paragraphs show how to do this on  
Windows. For other operating systems refer to the operating instructions of the PC.  
SmartNode 5200 Quick Start Guide  
3
 
1. Right-click on My Network Places and select Properties in the context menu (see figure 1).  
Figure 1. Displaying the Network Connections window  
Figure 2. Displaying the Internet Properties (TCP/IP) Properties window  
2. Double-click on Local Area Connection and click on Properties to open the Internet Protocol (TCP/IP)  
Properties window (see figure 2).  
3. Select Obtain an IP address automatically and Obtain DNS server address automatically options.  
4. Click OK to save changes and close the properties windows.  
4
SmartNode 5200 Quick Start Guide  
 
   
3.0 Connecting the SmartNode to your laptop PC  
First the SmartNode must be connected to the mains power supply with the power cable. Wait until the Power  
LED stops blinking and stays lit constantly. Now the SmartNode is ready.  
The interconnecting cables shall be acceptable for external use and shall be rated for the proper appli-  
cation with respect to voltage, current, anticipated temperature, flammability, and mechanical service-  
ability.  
CAUTION  
The SmartNode 5200 Series is equipped with Auto-MDX Ethernet ports, so you can use straight-through cables  
for host or hub/switch connections (see figure 3).  
Straight-through wired cable  
LAN (ETH 0/1)  
Laptop PC  
Figure 3. Connecting the SmartNode to your laptop PC  
The SmartNode comes with a built-in DHCP server to simplify configuration. Therefore, to automatically config-  
ure the PC for IP connectivity to the SmartNode, the laptop PC must be configured for DHCP. The SmartNode will  
provide the PC with an IP address. You can check the connection to the SmartNode by executing the ping com-  
mand from the PC command window as follows:  
ping 192.168.1.1  
SmartNode 5200 Quick Start Guide  
5
 
4.0 Configuring the desired IP address  
4.1 Factory-default IP settings  
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in the table  
below. Both Ethernet interfaces are activated upon power-up. LAN interface ETH 0/1 (LAN) provides a default  
DHCP server, the WAN interface uses DHCP client to automatically assign the IP address and network mask.  
IP Address  
Network Mask  
WAN interface Ethernet 0 (ETH 0/0) DHCP  
DHCP  
LAN interface Ethernet 1 (ETH 0/1)  
DHCP address range  
192.168.1.1  
192.168.1.10–192.168.1.19  
255.255.255.0  
255.255.255.0  
If these addresses match with those of your network, go to section 5.0 “Connecting the SmartNode to the  
network” on page 7. Otherwise, refer to the following sections to change the addresses and network masks.  
4.2 Login  
To access the SmartNode, start the Telnet application. Type the default IP address for the router into the address  
field: 192.168.1.1. Accessing your SmartNode via a Telnet session displays the login screen. Type the factory  
default login: administrator and leave the password empty. Press the Enter key after the password prompt.  
login:administrator  
password: <Enter>  
192.168.1.1>  
After you have successfully logged in you are in the operator execution mode, indicated by > as command line  
prompt. With the commands enable and configure you enter the configuration mode.  
192.168.1.1>enable  
192.168.1.1#configure  
192.168.1.1(cfg)#  
4.3 Changing the WAN IP address  
Select the context IP mode to configure an IP interface.  
192.168.1.1(cfg)#context ip router  
192.168.1.1(ctx-ip)[router]#  
Now you can set your IP address and network mask for the interface ETH 0/0 (WAN). Within this example a net-  
work 172.16.1.0/24 address is assumed. The IP address in this example is set to 172.16.1.99 (you should set  
this the IP address given to you by your network provider).  
192.168.1.1(ctx-ip)[router]#interface eth0  
192.168.1.1(if-ip)[eth0]#ipaddress 172.16.1.99 255.255.255.0  
2002-10-29T00:09:40 : LOGINFO  
2002-10-29T00:09:40 : LOGINFO  
172.16.1.99(if-ip)[eth0]#  
: Link down on interface eth0.  
: Link up on interface eth0.  
6
SmartNode 5200 Quick Start Guide  
 
Copy this modified configuration to your new start-up configuration. This will store your changes in non-volatile  
memory. Upon the next start-up the system will initialize itself using the modified configuration.  
172.16.1.99(if-ip)[eth0]#copy running-config startup-config  
172.16.1.99(if-ip)[eth0]#  
The SmartNode can now be connected to your network.  
5.0 Connecting the SmartNode to the network  
In general, the SmartNode will connect to the network via the WAN (ETH 0/0) port. This enables the SmartNode  
to offer routing services to the PC hosts on LAN (ETH 0/1) port. The SmartNode 5200 Series is equipped with  
Auto-MDX Ethernet ports, so you can use straight-through or crossover cables for host or hub/switch connections  
(see figure 4).  
The interconnecting cables shall be acceptable for external use and shall be rated for the proper appli-  
cation with respect to voltage, current, anticipated temperature, flammability, and mechanical service-  
ability.  
CAUTION  
LAN  
Straight-through wired or crossover cable  
WAN (ETH 0/0)  
LAN (ETH 0/1)  
Network  
Figure 4. Connecting the SmartNode to the network  
You can check the connection with the ping command from the SmartNode to another host on the network.  
172.16.1.99(if-ip)[eth0]#ping <IP Address of the host>  
Note If the WAN address is not set to DHCP, to ping a device outside your local LAN you must first configure  
the default gateway. (For information on configuring the default gateway, refer to section “Set IP  
addresses” in Appendix C, “Command Summary” of the SmartNode Series SmartWare Software Config-  
uration Guide.)  
SmartNode 5200 Quick Start Guide  
7
 
 
6.0 Loading the configuration (optional)  
Patton provides a collection of configuration templates on the CD-ROM that came with the SmartNode device—  
and also on the support page at www.patton.com/voip—one of which may be similar enough to your  
application that you can use it to speed up configuring the SmartNode. Simply download the configuration note  
that matches your application to your PC. Adapt the configuration as described in the configuration note to your  
network (remember to modify the IP address) and copy the modified configuration to a TFTP server. The Smart-  
Node can now load its configuration from this server.  
Note Patton regularly adds new configuration templates to the collection at www.patton.com/voip, so if  
you do not see your application on the CD-ROM, it may have been added to the website.  
Note If your application is unique and not covered by any of Patton’s configuration templates, you can man-  
ually configure the SmartNode instead of loading a configuration file template. In that case, refer to the  
SmartNode Series SmartWare Software Configuration Guide for information on configuring the Smart-  
Node device.  
In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration  
named SN.cfg in the root directory of the TFTP server.  
config  
Download...100%  
172.16.1.99(if-ip)[eth0]#  
After the SmartNode has been rebooted the new startup configuration will be activated.  
When you issue the reload command, the SmartNode will ask if you want to copy the running config-  
uration to the startup configuration. Since you just downloaded a configuration file to the startup con-  
figuration you must answer this question with NO. Otherwise, the downloaded configuration will be  
overwritten and lost!  
IMPORTANT  
172.16.1.99(if-ip)[eth0]#reload  
Running configuration has been changed.  
Do you want to copy the 'running-config' to the 'startup-config'?  
Press 'yes' to store, 'no' to drop changes : no  
Press 'yes' to restart, 'no' to cancel : yes  
The system is going down  
7.0 Additional information  
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,  
refer to the SN5200 Getting Started Guide and SmartNode Series SmartWare Software Configuration Guide on  
the CD-ROM.  
8
SmartNode 5200 Quick Start Guide  
 
A.0 Customer and Technical Support  
If you contact Patton support, you should have some system information ready to help us better help you. This  
information allows us to quickly identify what product you are using and how it is configured. Therefore, we inte-  
grated a “system report” page that collects all relevant information and presents it to you on one web page.  
Click on “Support” to access this page – the page also gives you instructions on where to send the report.  
Toll-Free VoIP support: call sip:[email protected] with a VoIP SIP client  
Online support: www.patton.com  
E-mail support: [email protected]—answered within 1 business day  
Telephone support:  
Standard: +1 (301) 975-1007 (USA), Monday–Friday: 8:00 am to 5:00 pm EST (1300 to  
2200 UTC/GMT)  
Alternate: +41 (0)31 985 25 55 (Switzerland), Monday–Friday: 8:00 am to 5:00 pm CET (0900 to 1800  
UTC/GMT)  
Fax: +1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 (Switzerland)  
A.0 Appendix—Factory default IP addresses  
Factory default IP addresses and netmask configuration.  
IP Address  
DHCP Client  
192.168.1.1  
Network mask  
n/a  
255.255.255.0  
255.255.255.0  
WAN interface Ethernet 0 (0/0)  
LAN interface Ethernet 1 (0/1)  
DHCP server address range (LAN)  
192.168.1.10-192.168.1.19  
SmartNode 5200 Quick Start Guide  
9
 
B.0 Compliance Information  
B.1 Compliance  
EMC Compliance:  
EN55022, Class A  
EN55024  
Low-Voltage Directive (Safety Compliance):  
IEC/EN60950-1, 2nd edition  
AS/NZS60950-1  
PSTN:  
TBR3:1995 A1  
AS/ACIF SO31:2001  
B.2 CE Declaration of Conformity  
This device conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of  
the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of  
their conformity.  
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above  
directive is indicated by CE mark on the device.  
B.3 Authorized European Representative  
D R M Green  
European Compliance Services Limited.  
Avalon House, Marcham Road  
Abingdon,  
Oxon OX14 1UD, UK  
10  
SmartNode 5200 Quick Start Guide  
 
Copyright statement  
Copyright © 2010, Patton Electronics Company. All rights reserved.  
The information in this document is subject to change without notice. Patton Electronics assumes no  
liability for errors that may appear in this document.  
Trademarks statement  
The term SmartNode is a trademark of Patton Electronics Company. All other trademarks presented in this docu-  
ment are the property of their respective owners.  
Warranty, Trademark, & Compliance Information  
For warranty, trademark and compliance information, refer to the SmartNode 5200 Getting Started Guide located  
on the CD-ROM shipped with your SmartNode device or available online at www.patton.com.  
In accordance with the requirements of council directive 2002/96/EC on Waste of  
Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate  
this product from other waste and scrap and deliver to the WEEE collection system in  
your country for recycling.  
SmartNode 5200 Quick Start Guide  
11  
 
NOTES  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
____________________________________________________________________  
12  
SmartNode 5200 Quick Start Guide  
 

Milwaukee Cordless Drill 0721 20 User Manual
Milwaukee Scanner 2291 20 User Manual
Nady Systems Home Theater System PPA 300 User Manual
NEC Network Router Express5800 GP Server User Manual
NEC Network Router xen mail cti User Manual
Numark Industries Musical Instrument DM 950 User Manual
Omron Blood Pressure Monitor M10 IT User Manual
Onkyo Stereo Receiver TX SR603X User Manual
Optimus Speaker PRO SWS300 User Manual
Panasonic Air Conditioner CS E7GKR User Manual