Paradyne Network Card MIM 2000F User Manual

MIM-2000F  
Installation Instructions  
Document Number MIM2-A2-GZ42-00  
June 2005  
Contents  
Software and Firmware License Agreement  
ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS  
TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED  
INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU  
SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.  
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS  
LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS  
ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE  
LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE  
LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU  
WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT  
PURCHASED BY YOU.  
The terms and conditions of this License Agreement (the “Agreement”) will apply  
to the software and/or firmware (individually or collectively the “Software”)  
incorporated into the Paradyne product (the “Product”) purchased by you and any  
derivatives obtained from the Software, including any copy of either. If you have  
executed a separate written agreement covering the Software supplied to you  
under this purchase, such separate written agreement shall govern.  
Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to  
accept a personal, non-transferable, non-exclusive, right (without the right to  
sublicense) to use the Software, solely as it is intended and solely as incorporated  
MIM2-A2-GZ42-00  
June 2005  
1
 
 
Product Documentation Online  
Complete documentation for Paradyne products is available at  
www.paradyne.com. Select Support Technical Manuals.  
To order a paper copy of a Paradyne document, or to speak with a sales representative,  
please call 1-727-530-2000.  
Unpacking and Inspecting the Equipment  
HANDLING PRECAUTIONS FOR  
STATIC-SENSITIVE DEVICES  
!
This product is designed to protect sensitive components from damage  
due to electrostatic discharge (ESD) during normal operation. When  
performing installation procedures, however, take proper static control  
precautions to prevent damage to equipment. If you are not sure of the  
proper static control precautions, contact your nearest sales or service  
representative.  
If there is any visible damage, do not attempt to install the MIM-2000F; contact  
your sales representative.  
Installing the MIM-2000F  
The MIM-2000F Micro Interface Module provides additional uplink ports for the  
BSX8000-5 Broadband Services Switch or 4929 DSLAM.  
MIM-2000F  
Lnk  
1
Act  
Lnk  
2
Act  
05-17669  
All MIMs are hot-swappable, although removal of a MIM disengages the upstream  
network connection for the DSLAM.  
To install the MIM-2000F:  
Procedure  
1. Using a flat-blade screwdriver to loosen the fastening screws, remove the  
cover plate from the MIM port on the front of your BSX8000 or 4929 DSLAM.  
CAUTION: The cover plate should be stored for possible future use. If the MIM  
is removed from your BSX8000 or DSLAM, it must be replaced with either  
another MIM or a cover plate. Do not operate a BSX8000 or DSLAM with an  
open MIM port.  
2. Align the MIM-2000F with the module guides inside the MIM port.  
MIM2-A2-GZ42-00  
June 2005  
3
 
     
3. Slide the MIM-2000F firmly into place. Do not use excessive force.  
4. Secure the MIM-2000F by tightening the fastening screws on the MIM  
faceplate with a flat-blade screwdriver.  
Installing and Cabling SFP Transceivers  
Both SFP copper and fiber optic transceivers may be installed in the MIM-2000F.  
The following SFP fiber optic transceivers are available:  
SFP-MMF – GigE SFP Multimode Fiber Optic Transceiver, Short Reach  
SFP-SMF10 – GigE SFP Single Mode Fiber Optic Transceiver, 10Km Reach  
SFP-SMF40 – GigE SFP Single Mode Fiber Optic Transceiver, 40Km Reach  
SFP-SMF80 – GigE SFP Single Mode Fiber Optic Transceiver, 80Km Reach  
MIM-2000F  
1
Lnk  
1
Act  
k  
2
A
c
t
05-17670  
To install SFP transceivers in the MIM-2000F:  
Procedure  
1. Insert an SFP transceiver into an SFP socket on the MIM-2000F.  
2. Insert the LC connector of your fiber optic cable into the SFP transceiver.  
3. Observing the minimum bend radius for your cable, fasten it in such a way that  
it will not be kinked or snagged in the course of other cabling. If you do not  
know the specifications for your cable, maintain a radius of at least ten times  
the cable diameter.  
4. Repeat for all the sockets you intend to use.  
Managing the MIM-2000F  
The configuration and monitoring of the integrated switch on the MIM-2000F is  
performed through the management screens of the BSX8000 or 4929 DSLAM that  
hosts this module. See the BSX8000-5 Installation Instructions or 4929 DSLAM  
Installation Guide and the NMS User’s Guide.  
4
June 2005  
MIM2-A2-GZ42-00  
 
   
LED Indicators  
Each port is associated with two LEDs: Lnk (Link) and Act (Active):  
Table 1. Front Panel LEDs  
LED  
State  
Indication  
Lnk (Link)  
Solid green  
No illumination  
Connection is established  
Connection is not established  
No data activity on the circuit  
Data is flowing through the circuit  
Act (Active) No illumination  
Flashing amber  
Regulatory Notices  
!
!
UNITED STATES – EMI NOTICE:  
This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to Part 15 of the FCC rules. These limits  
are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
The authority to operate this equipment is conditioned by the  
requirements that no modifications will be made to the equipment  
unless the changes or modifications are expressly approved by  
Paradyne Corporation.  
!
CANADA – EMI NOTICE:  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003  
du Canada.  
MIM2-A2-GZ42-00  
June 2005  
5
 
   
!
EUROPEAN REGULATORY COMPLIANCE  
The following regulatory compliance information applies to the  
MIM-2000F as installed in the 4929 DSLAM or BSX8000-5 Broadband  
Services Switch:  
This Class A product complies with European Norm EN55022.  
Warning: In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate  
measures to correct the situation.  
Warranty, Sales, Service, and Training Information  
Contact your local sales representative, service representative, or distributor  
directly for any help needed. For additional information concerning warranty, sales,  
service, repair, installation, documentation, training, distributor locations, or  
Paradyne worldwide office locations, use one of the following methods:  
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.  
(Be sure to register your warranty at www.paradyne.com/warranty.)  
Telephone: Call our automated system to receive current information by fax or  
to speak with a company representative.  
— Within the U.S.A., call 1-800-870-2221  
— Outside the U.S.A., call 1-727-530-2340  
*MIM2-A2-GZ42-00*  
*MIM2-A2-GZ42-00*  
Copyright 2005 Paradyne Corporation. Printed in U.S.A.  
6
June 2005  
MIM2-A2-GZ42-00  
 
 

Miglia Technology Cordless Telephone Cordless Phone User Manual
Moxa Technologies Video Game Console UC 7122 User Manual
Murphy Portable Generator A900 Series User Manual
NEC Tool Storage WM 46UN L User Manual
NeumannBerlin Microphone U 89 i User Manual
Nexus 21 Refrigerator CAPTEUR DE PROFONDEUR User Manual
Nokia Headphones HS 6 User Manual
NordicTrack Treadmill NTTL10610 User Manual
Optiview Security Camera CLPIN User Manual
Orion Car Audio Car Amplifier XTR10001 User Manual