Panasonic Network Card AW PS300 User Manual

AC Adapter  
AW-PS300  
Before attempting to connect or operate this product,  
please read these instructions completely.  
 
CONTENTS  
FEATURES ................................................................................................................................................................................... 1  
PRECAUTIONS ............................................................................................................................................................................. 2  
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ...................................................................................................... 3  
CONNECTION .............................................................................................................................................................................. 6  
SPECIFICATIONS ......................................................................................................................................................................... 8  
ACCESORY ................................................................................................................................................................................... 8  
FEATURES  
• This is the AC Adapter for the Pan/tilt Head AW-PH300.  
• It has an AC outlet (500 W maximum) for halogen  
lamps that can be switched on and off from a Control  
Panel (AW-RP301, AW-RP305, AW-RP501, or AW-  
RP505).  
• The maximum allowable cable length between this  
adapter and pan/tilt head is 30 meters.  
• It also has an option switch (120V, 1A maximum)  
whose contact can be shorted or opened from a  
Control Panel (AW-RP301, AW-RP305, AW-RP501, or  
AW-RP505).  
-1-  
 
PRECAUTIONS  
• Handle the adaptor with care.  
Dropping the control panel or subjecting it to a strong  
shock can cause a failure or an accident.  
• Care  
Pull out the power cable plug, and wipe the control  
panel clean with a dry cloth. If it is extremely dirty, dip  
a cloth into a diluted solution of kitchen detergent,  
squeeze it hard, and wipe the product surfaces care-  
fully.  
• Operating temperature range –10°C to +45°C  
Avoid using it in a cold place below –10°C or a hot  
place above +45°C because low or high temperature  
will adversely affect the parts inside.  
Note  
• Do not use benzine, paint thinner, or other volatile  
liquids.  
• When using a chemical duster, carefully read the  
caution notes on its use.  
• Switch power off before power cable connection or  
disconnection.  
Be sure to switch power off before connecting or dis-  
connecting the power cable.  
• Avoid outdoor use.  
• Install the control panel more than 1 meter away  
from the monitors.  
-2-  
 
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS  
FRONT PANEL  
FUSE(POWER)  
FUSE(LAMP)  
POWER  
F U S E  
F U S E  
OFF  
ON  
O
I
FUSE  
FUSE  
T
T
AC Adaptor  
AW-PS300  
125V 3.15A  
125V 6.3A  
POWER  
q Power Switch (POWER, ON/OFF)  
e Fuse [FUSE (POWER)]  
Power is switched on to supply power to the pan/tilt  
head when this switch is pressed to the ON position  
(POWER Indicator lights), and is switched off when the  
switch is pressed to the OFF position.  
Power fuse. Use a 125V, 3.15A fuse to replace it.  
r Lamp Fuse [FUSE (LAMP)]  
Halogen lamp fuse. Use a 125V, 6.3A fuse to replace  
it.  
w Power Indicator (POWER)  
Lights red when POWER ON/OFF Switch q is pressed  
to the ON position, and goes out when POWER  
ON/OFF Switch q is pressed back to the OFF position.  
-3-  
 
FRONT PANEL  
LAMP AC OUT  
100V 500W  
AC IN  
OPTION SW OPTION SW  
CONTROL OUT CONTROL IN  
OP  
LAMP  
DC 15V  
OUT  
CONTROL  
C
S
+
t AC 120V Inlet [AC IN](AC 3P Inlet)  
y to short or open, using a cable (to be locally pur-  
chased) with a nominal cross section of 0.3 mm or  
2
Connect the supplied AC cable.  
more that meets the UL specifications. The maximum  
allowable cable length is 30 meters.  
Applicable Wire  
y Option Switch Terminal (OPTION SW CONTROL  
OUT) (2P Terminal Board)  
A relay switch capable of controlling the contact to  
short or open from a Control Panel (AW-RP301, AW-  
RP305, AW-RP501, or AW-RP505). The terminal board  
has a maximum capacity of 120 V, 1 A (AC/DC), and is  
valid when it is connected to OPTION SW CONTROL IN  
Terminal u on the pan/tilt head.  
Solid wire:  
Stranded wire:  
Usable wire range  
Solid wire:  
ø1.02 (AWG 18)  
0.75 mm  
2
ø0.64 to ø1.02  
(AWG 22 to 18)  
2
2
Stranded wire:  
0.3 mm to 0.75 mm  
(AWG 22 to 20)  
Strand diameter: ø0.18 or more  
Standard bare end length 10 mm  
u Option Switch Control Input Terminal (OPTION SW  
CONTROL IN) (1P Terminal Board)  
Connect it to OP Output Terminal on the pan/tilt head  
when controlling OPTION SW CONTROL OUT Terminal  
-4-  
 
i Lamp Control Input Terminals (LAMP CONTROL  
C/S) (2P Terminal Board)  
Applicable (usable) wire  
Solid wire:  
ø1.29 (AWG 16)  
2
Connect it to LAMP CONTROL C/S Terminals on the  
pan/tilt head when controlling the halogen lamp con-  
nected to LAMP AC OUT Connector ! to switch it on  
and off, using a cable (to be locally purchased) with a  
Stranded wire:  
1.25 mm (AWG 16)  
Strand diameter ø0.18 or more  
Standard bare end length  
11 mm  
2
nominal cross section of 0.3 mm or more that meets  
! Lamp AC Output Connector [LAMP AC OUT]  
(AC 3P Outlet)  
the UL specifications. The maximum allowable cable  
length is 30 meters.  
Applicable wire  
AC Output Connector for halogen lamps to be  
switched on and off from a Control Panel (AW-RP301,  
AW-RP305, AW-RP501, or AW-RP505). Locally pur-  
chase an AC plug conversion cable that matches the  
AC plug for the halogen lamp to be used. Connect a  
halogen lamp of 250 W to 500 W. If a halogen lamp of  
less than 250 W is connected, the LAMP Indicator on  
the control panel may flash to indicate a burnt bulb  
even though the lamp is normal.  
Solid wire:  
Stranded wire:  
Usable wire range  
Solid wire:  
ø1.29 (AWG 16)  
1.25 mm (AWG 16)  
2
ø0.64 to ø1.29  
(AWG 22 to 16)  
2
2
Stranded wire:  
0.3 mm to 1.25 mm  
(AWG 22 to 16)  
Strand diameter ø0.18 or more  
Standard bare end length 11 mm  
o DC 15V Output Terminal (DC 15V OUT +/–)  
(2P Terminal Board)  
Connect it to (DC 15V IN +/– Terminals) on the pan/tilt  
head with a cable (to be locally purchased) with a nom-  
2
inal cross section of 1.25 mm or more that meets the  
UL specifications. The maximum allowable cable  
length is 30 meters.  
-5-  
 
CONNECTION  
• Switch off all the devices before making any connec-  
tion.  
• Use the Pan/tilt Head AW-PH300.  
Applicable wire  
Solid wire:  
Stranded wire:  
Usable wire range  
Solid wire:  
ø1.29 (AWG 16)  
1.25 mm(AWG16)  
2
• Connect the DC 15V OUT Terminals [+] and [–] on this  
adapter to the DC 15V IN Terminals [+] and [–] on the  
Pan/tilt Head (AW-PH300) respectively with cables (to  
be locally purchased) with a nominal cross section of  
ø0.64 to 1.29 (AWG 22 to 16)  
2
2
Stranded wire:  
0.3 mm to 1.25 mm  
2
(AWG 22 to 16)  
1.25 mm or more that meets the UL specifications.  
Strand diameter ø0.18 or more  
Standard bare end length: 11 mm  
The maximum allowable cable length between the  
adapter and pan/tilt head is 30 meters.  
Applicable (usable) wire  
• To control the option switch terminal to short or open  
from the control panel, connect the OPTION SW CON-  
TROL IN Terminal [OP] on the adapter to the OP  
Output Terminal on the pan/tilt head with a cable (to be  
locally purchased) with a nominal cross section of 0.3  
Solid wire:  
Stranded wire:  
ø1.29 (AWG 16)  
1.25mm (AWG 16)  
2
Strand diameter ø0.18 or more  
Standard bare end length:  
11 mm  
2
mm or more that meets the UL specifications. The  
• To switch on and off the halogen lamp from the control  
panel, connect the LAMP CONTROL Input Terminals  
[C] and [S] to the LAMP CONTROL Output Terminals  
[C] and [S] on the pan/tilt head respectively with cables  
(to be locally purchased) with a nominal cross section  
maximum capacity of the option switch terminal is  
120V 1A (AC/DC).  
Applicable wire  
Solid wire:  
Stranded wire:  
Usable wire range  
Solid wire:  
ø1.02 (AWG 18)  
2
2
0.75 mm  
of 0.3 mm or more that meets the UL specifications.  
The maximum allowable cable length is 30 meters.  
Locally purchase an AC plug conversion cable that  
matches the AC plug for the halogen lamp to be used,  
and connect a halogen lamp of 250 W to 500 W to the  
lamp AC outlet. If a halogen lamp of less than 250 W is  
connected, the LAMP Indicator on the control panel  
may flash to indicate a burnt bulb even though the  
lamp is normal.  
ø0.64 to 1.02 (AWG 22 to 18)  
2
2
Stranded wire:  
0.3 mm to 0.75 mm  
(AWG 22 to 20)  
Strand diameter ø0.18 or more  
Standard bare end length: 10 mm  
• For details on the connection, refer to the Operating  
Instructions.  
-6-  
 
• For a detailed description of con-  
necting the individual devices,  
refer to their Operating  
Instructions.  
• Connect the supplied AC cable to  
the AC 120V inlet. Plug the AC  
cable to an AC outlet, and press  
the power switch on the adapter  
to the ON position.  
Pan/tilt Head  
AW-PH300  
Lamp Control Cable  
(Nominal cross section 0.3 mm or  
Halogen Lamp  
2
more, to be locally purchased)  
* Unnecessary if lamp control is  
not needed.  
DC cable  
(Nominal cross section 1.25 mm or  
more, to be locally purchased)  
2
Option switch control cable  
2
(Nominal cross section 0.3 mm or  
more, to be locally purchased)  
* Unnecessary if option switch  
control is not needed.  
LAMP AC OUT  
100V 500W  
AC IN  
OPTION SW OPTION SW  
CONTROL OUT CONTROL IN  
OP  
LAMP  
DC 15V  
OUT  
CONTROL  
C
S
+
Locally purchase an AC plug conversion  
cable that matches the halogen lamp AC  
plug.  
* Unnecessary if no halogen lamp is con-  
nected.  
AC Cable  
(supplied)  
Option Unit  
120V AC  
60Hz  
-7-  
 
SPECIFICATIONS  
Source Voltage:  
Input Capacity:  
Power Output:  
120 V AC 60 Hz  
552W  
DC 15V OUT: DC15V 2.5A, with over-current protect circuit  
LAMP AC OUT: 120V AC, max. 500W, min. 250W  
Pan/tilt head connecting  
cables:  
5 cables (2 DC power cables, 2 lamp control cables, 1 option switch control cable)  
(in case of using the lamp control and option switch control functions)  
Maximum cable length  
Operating temperature:  
Dimensions:  
30 m  
–10°C to +45°C (14°F to 113°F)  
210(W) x 51(H) x 250(D) mm  
8-1/4”(W) x 2”(H) x 9-7/8”(D)  
2.5 kg (5.5 lbs.)  
Weight:  
Finish:  
AV Ivory baking  
Weight and dimensions indicated are approximate.  
Specifications are subject to change without notice.  
ACCESORY  
AC Cable .......................................................................1 pc.  
-8-  
 
Broadcast & Television Systems Company  
Division of Matsushita Electric Corporation of America  
Executive Office: One Panasonic Way 2E-6, Secaucus, NJ 07094  
Regional Offices:  
EASTERN ZONE: 43 Hartz Way, Secaucus, NJ 07094 (201) 348-7620  
CENTRAL ZONE: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5200  
SOUTHERN ZONE:  
Atlanta Region: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30174  
Panazip 11 (770) 338-6841, fax (770) 338-6741  
Law Enforcement Video Products: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA  
30174, Panazip 11 (770) 338-6844, fax (770) 338-6721  
WESTERN ZONE:  
Los Angeles Region: 6550 Katella Ave. 17A-1, Cypress, CA 90630 (714) 373-7271  
Government Marketing Department: 52 West Gude Drive, Rockville, MD 20850 (301) 738-3840  
PANASONIC CANADA INC.  
5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905) 624-5010  
PANASONIC SALES COMPANY  
DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC.  
San Gabriel Industrial Park, 65th Infantry Ave. KM. 9.5 Carolina, Puerto Rico 00630 (809) 750-4300  
N1197-0  
7J1A110A  
Printed in Japan  
 

Miele Convection Oven h 4331 User Manual
Multiquip Portable Generator DCA 300SSK User Manual
Napa Essentials Battery Charger 85 510 User Manual
NETGEAR Network Router AC1200 User Manual
Network Computing Devices Network Card GW EN11H User Manual
Nikon Camera Lens 2190 User Manual
Nikon Digital Camera 25446 User Manual
Omega Automobile Parts HHT21A User Manual
Panasonic Blu ray Player DMP BD45 User Manual
Panasonic Universal Remote EUR511155 User Manual