BMI BODY WEIGHT MONITOR
MODEL : BWR102
USER’S MANUAL
ADJUST THE SETTING OF THE REMOTE DISPLAY UNIT
1. enter the setting mode.
set
2. set the display format.
1
2
set
set
set
set
set
set
set
3. set the hour.
1
2
4. set the minute.
1
2
5. set the year.
1
2
6. set the date-month format.
7. set the month.
8. set the date.
1
2
1
2
1
2
1
STORE WEIGHT TO REMOTE DISPLAY UNIT
1. take measurement from scale.
2. activate receiving mode.
1
Note:
30
Beep sound to indicate the
activation of receiving mode.
Receiving function will be activated
for 30 sec.
3. weight received from scale.
Note:
2
Beep sound to indicate signal is
being received from the scale.
If the height is not set, there will not
have BMI displayed.
4. select the user.
1
1
2
5. store the weight.
1
Note:
Beep sound to indicate the
weight is stored to memory.
No memory for guest mode.
7
2
3
USER SETTING / MEMORY RECALL FROM THE REMOTE DISPLAY UNIT
1a. select the user.
1
1
2
Note:
If the height is not set, there
will not have height displayed.
1b. quit user mode.
1
2a. recall memory.
1
2
3
mem
mem
2
2b. set the heigt.
1
2
3
set
set
4
TIPS
A. install the batteries to the unit.
B. when battery is first installed on both scale and remote display unit.
B-1. acquire weight on scale.
B-2. match the remote display unit with the scale.
Note:
a) beep sound to indicate the matching is activated.
b) check the reading on scale and remote display unit .
c) if fail, repeat step B-1 & B-2.
B-3. set the clock.
C. after changing batteries of the scale, repeat step B-1 & B-2.
D. after changing batteries of the remote display unit, set the clock only.
E. replace all batteries when
F. replace battery when
appears on the scale.
for scale or
for remote display unit appears on remote display unit.
G. memory stored in remote display unit will not be ereased after changing batteries.
H. if there exist irregularity in weighing, press reset on the scale and then repeat step B-1 & B-2.
Note:
a) place a blunt stylus into the slot to press be reset.
b) after reset please wait for few seconds for the scale to self-calibrate.
I. allow the scale to settle for around 30 min if there is a sudden change in embient environment . eg. from
an air conditioned room to an open area.
If not disposed of properly, batteries can be harmful. Protect the environment by taking
exhausted batteries to authorized disposal stations.
To extend battery life, when battery power is low, replace all the batteries.
5
WHAT IS BODY MASS INDEX (BMI) ?
Body Mass index (BMI) is a measurement of your body height to weight ratio. BMI is the most widely used
an international standard for evaluating obesity. It is expressed as your body weight in kilograms divided by
the square of your body height in meters.
BMI =
body weight (kg)
[body height (m)]2
It can be used as indication to estimate whether you are overweight or underweight.
According to various statistics when BMI closes to 22, the mortality rate is the minimal thus the health
condition is most ideal.
The following can be used as a guidance reference for the interpretation of BMI reading.
BMI is low :
You have low amount of body fat. It will be desirable if you are an athlete. If your body weight and BMI is
low and you are not an athlete, it is suggested you to gain weight through a balance diet and exercise to
improve your own immunity.
BMI is average :
This shows an ideal BMI - your amount of body fat is at healthy level. It shows the lowest incidence for you
to have serious illness.
BMI is high :
This is the board line. Your risk to get illness increases. It is better to lower your body weight through diet
and exercise.
BMI is very high :
This is an unhealthy situation. You are excessive prosperity. You are at high risk to get heart disease, high
blood pressure and other series illness. It is strongly recommended you to lose weight by changing the diet
and execise more.
Mortality Rate
BMI value
22
Asian
Level
BMI
Low
Average
High
Very High
19.7 or less
19.8~24.1
24.2~26.3 26.4 or more
Non-Asian
Level
Low
Average
High
Very High
BMI
19.9 or less
20.0~24.9
25.0~26.9 30.0 or more
Important : Please consult your doctor for the diet program.
6
TROUBLE SHOOTING
Symptom
Description
Action
1.
incorrect use or weight
measured is not stable.
step off the scale first and
repeat the measurement.
2.
3.
scale overloaded.
be sure no excessive mass is put
on scale and then repeat the
measurement.
no data of height is input for
BMI or BMI is out of range.
check the height and repeat the
measurement
NOTES FOR THE USER
MAX
150kg
A. maximum capacity: 150 kg / 330 lb / 23st8lb
B. graduation: 0.1 kg / 0.2 lb
100g
C. height input range : 94.0 - 240.0 cm / 3’1.0” - 7’10.5”
D. BMI measurement range : 5 - 50 kg / m2
BMI
E. use additional foot pad for use on carpet
F. power: scale - 4 x LR6 / AA / UM-3 1.5V batteries;
remote display unit - 4 x LR6 / AA / UM-3 1.5V batteries
G. avoid soft and unlevelled grounding
H. do not store the scale erect
7
I. do not load the scale when not in use
J. avoid from wet
K. avoid from abrasive or corrosive cleaning agent
EC-DECLARATION OF CONFORMITY
This product contains the approved transmitter module TX 01 and complies with the essential requirements
of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following
standard(s) has/have been applied:
Efficient use of radio frequency spectrum
(Article 3.2 of the R&TTE Directive)
applied standard(s)
EN 300 220-1(2,3):1997
ETS 300 683:1997
EN 60950:1997
Electromagnetic compatibility
(Article 3.1.b of the R&TTE Directive)
applied standard(s)
Safety of information technology equipment
(Article 3.1.a of the R&TTE directive)
applied standard(s)
Additional information:
The product therefore conforms with the Low Voltage Directive 73/23/EC, the EMC Directive 89/336/EC
and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking.
VS-Villingen / Germany August 2001
Gerhard Preis
EC representative of manufacturer
RTTE Compliant Countries :
All EU countries, Switzerland CH
And Norway
N
8
GB
Legend:
``
Key
-
-
Press
Press and hold
key
-
Flashing
F
D
I
Légende:
Legende:
Legenda:
Leyenda:
-
Key Appuyer
Key
key
-
-
Key Appuyer et maintenir appuyer
Clignotant
- Betätigen
Key
key
- Gedrückt halten
- Blinkt
-
-
Premere il tasto
Key
key
Premere il tasto e tenerlo premuto
-
Flashing lampeggiante
-
Pulsar
ES
Key
key
-
-
Pulsar y mantener oprimido
Parpadeando
-
-
Pressione
Legenda:
P
Key
key
Pressione e segure
-
Intermitente
NOTE FOR THE USER
·
·
Please read the manual carefully before use.
The scale will calibrate automatically to provide accurate measurement when the scale is placed on the ground. Message:
will be displayed on the scale to indicate the calibration is in process. Normally it will take 2-3 seconds
only. Please leave the scale alone when you see such message.
,
11
|