RX3 Plus English
Introduction
The OMRON RX3 Plus measures your blood pressure and pulse simply and
quickly from the wrist,
without the use of an inflation bulb or stethoscope. The measurement
values are stored in the memory of the OMRON RX3 Plus. The OMRON
RX3 Plus fits wrist circumferences from 13.5 to 19.5 cm.
1
Digital Automatic
Blood Pressure Monitor
Instruction manual
page
1
RX3 Plus English
1 How to obtain meaningful blood pressure readings
General
• The OMRON RX3 Plus is not suitable for measuring the frequency of
cardiac pacemakers.
• Consult your doctor during pregnancy, arrhythmia and arteriosclerosis.
• Avoid eating, drinking (alcohol), smoking, sport and taking a bath before
measurement.
• Be calm and relaxed before and during measurement.
• You should never change the dose of medicines prescribed by your
doctor.
Tips for use
• Check your blood pressure at least twice a day (before breakfast, after
work).
• Do not measure your blood pressure while you are in a vehicle.
• Always measure on the same wrist, prefer your left wrist for a comfortable
use.
• Wrap the wrist cuff around your wrist before start of measurement.
Caution
• Operating temperature between 10°C and 40°C.
• Operating environment must be free from excessive vibrations, shocks,
magnetic fields, electrical noise, etc.
• Stay out of sunlight during measuring.
• Keep portable phones 5 meters away during measurement.
• Do not wrap the cuff other than around your wrist.
• Do not drop the OMRON RX3 Plus.
3
RX3 Plus English
2 Overview
A
B
C
D
E
F
G
A Display
E Memory button
B Wrist Cuff
C Set button
D Adjust button
F On/off button
G Battery Compartment
4
RX3 Plus English
3 Preparation
3.1 Insert batteries
1 Open the battery compartment.
2 Insert two batteries in the battery
compartment.
Caution! Use two identical 1.5V
alkaline batteries type AAA!
3 Close the battery compartment.
5
RX3 Plus English
3.2 Fit wrist cuff
Caution! Do not press on/off button when the wrist cuff is not wrapped
around the wrist!
S
Y
S
m
m
H
g
D
A
T
E
/T
IM
S
E
E
S
E
T
T
A
D
JU
S
T
D
M
I
A
m
P
U
m
L
H
g
S
E
/m
in
1 Bare your wrist.
2 Put the monitor on the inner side
Caution! Push up your sleeve:
avoid constricting the blood flow!
of your wrist.
S
Y
S
m
m
n
i
m
/
g
E
S
H
H
g
L
m
U
P
m
A
I
D
D
A
M
T
E
T
/T
IM
S
E
E
S
E
T
A
D
JU
S
T
S
T
U
J
D
A
T
E
T
S
E
T
E
S
M
I
T
/
M
E
D
I
A D
A
m
P
U
m
L
H
g
S
E
/m
g
in
H
m
m
S
Y
S
3 Hold the end of the wrist cuff and
wrap it around your wrist.
Caution! Be sure the wrist cuff fits
closely; do not pinch your arm!
Note: attach the monitor upside
down for reliable measurement at
your right wrist.
6
RX3 Plus English
4 Operation
4.1 Control functions
L
Q
H
J
C
D
DATE/TIME SET
SYSmmHg
SET
ADJUST
M
N
M
R
S
E
F
DIAmmHg
PULSE/min
K
P
T
C Set button
H Date.
D Adjust button
E Memory button
F On/off button
J Systolic blood pressure in
mmHg.
K Diastolic blood pressure in
mmHg.
L Memory display: 21 values in
memory.
M Average value of the latest 3
measurements displayed.
N Monitor blood pressure: flash -
measurement takes place, light
up - finish measurement.
P Pulse: heartbeats per minute.
Q Time.
R Inflation: wrist cuff inflates and
measurement starts.
S Deflation: wrist cuff deflates and
measurement finishes.
T Battery exhausted: batteries are
weak/exhausted.
7
RX3 Plus English
4.2 Set date and time
Note: each time you press adjust button year (2001-2030), month (1-12),
day (1-31), hour (0-23) and minutes (0-59) advance by one unit. Keep
button pressed to advance fast.
Note: use the grey coloured button to carry out the instruction.
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
SYSmmHg
SYSmmHg
SYSmmHg
M
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
1 Press set or adjust button.
2 Press set button for 2 seconds.
Press adjust button to set the
current year.
DATE/TIME SET
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
SYSmmHg
SET
ADJUST
SYSmmHg
SYSmmHg
SYSmmHg
M
M
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
3 Press set button to proceed to
month setting.
4 Press set button to proceed to
day setting.
Press adjust button to set the
current month.
Press adjust button to set the
current day.
8
RX3 Plus English
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
SYSmmHg
SYSmmHg
SYSmmHg
SYSmmHg
M
M
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
5 Press set button to proceed to
hour setting.
6 Press set button to proceed to
minute setting and
Press adjust button to set the
current hour.
press adjust button to set the
current minutes.
DATE/TIME SET
DATE/TIME SET
SYSmmHg
SET
ADJUST
SYSmmHg
SET
ADJUST
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
7 Press set button to complete setting.
8 Press on/off button.
4.3 Measurement
Caution! Allow an interval of at least three minutes between two
successive measurements!
DATE/TIME SET
SYSmmHg
S
E
T
ADJUST
M
DIAmmHg
PULSE/min
1 Sit comfortably upright with your feet flat on the floor.
Caution! The OMRON RX3 Plus should always be at heart height during
measurement!
9
RX3 Plus English
DATE/TIME SET
SET ADJUST
SYSmmHg
M
DIAmmHg
PULSE/min
2 Press on/off button to start measurement.
The OMRON RX3 Plus measures during inflation!
Caution! Sit still, do not move, do not speak and do not touch the
OMRON RX3 Plus!
4.4 Read display
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
SYSmmHg
SYSmmHg
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
1 Read the values of blood pressure and pulse from the display.
Note: display shows alternately date, blood pressures and time, heartbeats.
DATE/TIME SET
SYSmmHg
SET
ADJUST
M
DIAmmHg
PULSE/min
2 Note date, time and values in your
3 Press on/off button to turn off
personal blood pressure pass.
power.
10
RX3 Plus English
5 Memory
5.1 Recall average value
DATE/TIME SET
L
M
DATE/TIME SET
SET ADJUST
SYSmmHg
SYSmmHg
SET
ADJUST
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
L Memory display: 21 values in memory.
M Average value of the latest 3 measurements displayed.
1 Press memory button.
Note: display shows alternately blood pressures and heartbeats.
5.2 Recall previous values
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SET ADJUST
SYSmmHg
SYSmmHg
SYSmmHg
H
Q
M
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
H/Q Date/time of measurement.
1 Press memory button for latest and previous values.
Press on/off button to turn off power.
Note: display shows alternately date, blood pressures and time,
heartbeats.
11
RX3 Plus English
5.3 Erase memory
DATE/TIME SET
SET ADJUST
DATE/TIME SET
SYSmmHg
SYSmmHg
SET
ADJUST
M
M
DIAmmHg
PULSE/min
DIAmmHg
PULSE/min
1 Press memory button to turn on
power.
2 Press memory button and
simultaneously on/off button to
erase memory.
Caution! All stored values will be
erased!
Press on/off button to turn off power.
12
RX3 Plus English
6 Storage
• Store the OMRON RX3 Plus in the hard case in a dry, closed place with a
temperature between -20°C and 60°C.
• Remove the batteries if you not intend to use the OMRON RX3 Plus for 3
months or more.
7 Faults: causes and rectifications
Fault
Cause
Rectification
Correct reading Movement, sound
Wait for at least
not possible
Low voltage
vibration, weak pulse three minutes to
repeat
measurement
Batteries
Fit two new
weak/exhausted
identical 1.5V
alkaline batteries
type AAA
Display
empty
Inexplicable values
Wrong working
method
Follow instructions,
repeat
measurement
13
RX3 Plus English
8 Maintenance and spare parts
Cleaning instruction
battery compartment and insert
two new identical 1.5V alkaline
batteries type AAA.
• Use a soft, slightly moistened
cloth to clean the OMRON RX3
Plus and the wrist cuff.
Caution! Do not use petrol,
thinners or similar solvents!
Caution! Do not wash the wrist
cuff!
• Do not carry out repairs of any
kind yourself. If a defect occurs
consult your OMRON retail outlet
or distributor as mentioned on the
packaging.
Spare parts
• Due to high company quality
standards, OMRON considers the
main unit as a non-serviceable
part because the need for proper
calibration after replacement of
high tech components.
• If the cuff needs to be replaced
have this done by an authorised
expert. Consult your OMRON
retailer or OMRON distributor as
mentioned on the packaging.
Calibration
• It is recommended to have the
OMRON RX3 Plus inspected
every two years to ensure correct
function and accuracy. Consult
your OMRON retail outlet or
OMRON distributor as mentioned
on the packaging.
Attention! Disposal of batteries and
the OMRON RX3 Plus should be
carried out in accord-
ance with the national
regulations for the
disposal of electronic
products.
Replace batteries
• Remove the battery out of the
14
RX3 Plus English
9 Technical data
Product name
Model
OMRON Digital Blood Pressure Monitor
RX3 Plus
Display
Digital LCD
Measurement range
Accuracy
Inflation
Pressure: 0 - 299 mmHg / Pulse: 40 - 180 /minute
Pressure: 3 mmHg / Pulse: 5% of display reading
Automatic by electric pump
Deflation
Automatic rapid deflation system
Electrostatic capacity pressure sensor (capacitive)
Oscillometric method
Pressure detection
Measurement method
Memory
21 Measurements
Power supply
Battery life
2 x 1.5V Alkaline batteries AAA
New batteries will last for approx. 400 measurements
Operating temperature /humidity +10°C to +40°C / 30% to max. 85% relative humidity
Operating environment
Free from excessive vibrations, shocks, magnetic
fields, electrical noise, etc.
Storage temperature / humidity -20°C to +60°C / 10% to max. 95% relative humidity
Weight
Approx. 160 g including batteries
Outer dimensions
Wrist circumference
Accessories
Approx. 79 mm (W) x 47 mm (H) x 71 mm (D)
Approx. 13.5 cm to 19.5 cm
Instruction manual, guarantee card, blood pressure
pass, 2 alkaline batteries, storage box
Subject to technical modification without prior notice
Note
= Type B
Manufacturer
0197
OMRON HEALTHCARE Co., Ltd.
24, Yamanouchi Yamanoshita-cho, Ukyo-ku, Kyoto,
615-0084 Japan
EU-representative
OMRON HEALTHCARE EUROPE B.V.
Kruisweg 577, NL-2132 NA Hoofddorp
This device fulfils the provisions of the EC directive 93/42/EEC (Medical Device
Directive). This blood pressure monitor is designed according to the European
standard EN1060, Non-invasive sphygmomanometers Part 1: General Requirements
and Part 3: Supplementary requirements for electromechanical blood pressure
measuring systems.
15
RX3 Plus English
10 General information about blood pressure
Blood circulation
The blood circulation is responsible for supplying the body with oxygen.
Blood pressure is the pressure exerted on the arteries.
The systolic blood pressure value (higher pressure or top value)represents
the blood pressure produced by contraction of the heart muscle.
The diastolic blood pressure value (lower pressure or lower value)
represents the blood pressure produced by relaxation of the heart muscle.
Classification of blood pressure
The World Health Organisation (WHO) and the International Society of
Hypertension (ISH) developed the blood pressure classification. This
classification is based on the blood pressure values measured while sitting
on a chair in the outpatient department of a hospital.
Systolic blood pressure
(mmHg)
Severe hypertension
180
Moderate hypertension
160
Mild hypertension
140
Normal systolic value
130
Normal blood
pressure
120
Optimal blood
pressure
(target value)
Diastolic
blood
pressure
(mmHg)
80
85
90
100 110
According to the blood pressure classification by the WHO/ISH.
Health and blood pressure
The incidence of hypertension increases with age. In addition, a lack of
exercise, excess body fat and high levels of cholesterol (LDL), which sticks to
the inside in blood vessels, reduces elasticity of these vessels.
16
RX3 Plus English
Hypertension accelerates arterial sclerosis which can lead to very serious
conditions such as stroke and myocardial infarction. For these reasons it is
very important to know whether the blood pressure is within a healthy
range. Blood pressure fluctuates from minute to minute, throughout the
day. Therefore it is essential to take regular measurements to help you
identify an average blood pressure.
Symptoms of high blood pressure
High blood pressure can go unnoticed for a long time, since it does not
cause noticeable symptoms. The following are all possible causes of
abnormally high blood pressure:
• Overweight
• High cholesterol level
• Smoking
• Excessive alcohol consumption
• Stress and emotional upset
• Excessive consumption of salt
• Lack of physical exercise
• Genetic/hereditary predisposition
• Underlying illnesses, such as kidney disorders or endocrine disturbance
Blood pressure measurement
Measuring your blood pressure daily enables you to recognize high blood
pressure at an early stage and obtain medical treatment.
The oscillometric method of measurement determines your blood pressure
by measuring the pressure fluctuations caused by the pulse waves.
Since your blood pressure fluctuates within a day (see graphic next page),
you should always measure it at the same time each day to ensure that the
measurements are genuinely comparable. At the doctor’s surgery,
nervousness and tension may cause your blood pressure to be higher than
in familiar circumstances at home. This is known as “White Coat
Hypertension”.
17
RX3 Plus English
Treatment of high blood pressure
Upper curve: systolic blood pressure
Lower curve: diastolic blood pressure
200
150
100
50
6
12
18
24
Time of day
Example: fluctuation within a day (male, 35 years old)
If your blood pressure reaches upper values of 140 -160 mmHg and lower
values of 90 - 95 mmHg in repeated measurements over several days, you
should consult your doctor for detailed medical examination. You can
assist the treatment prescribed by your doctor in the following ways:
• Loose weight and lower your cholesterol level by reducing the calories
and fat in your diet. Cut down on animal fats and eat more fruit and
vegetables.
• Reduce the consumption of alcohol.
• Reduce the intake of salt: the German League for Combating High Blood
Pressure recommends six grams of salt per day (i.e. one teaspoon) on
average.
• Stop smoking.
• Take regular exercise.
• Monitor your blood pressure.
18
|