Omron Healthcare Blood Pressure Monitor 7300W User Manual

INSTRUCTION MANUAL  
Women’s Advanced  
Automatic Blood Pressure Monitor  
with Two Cuffs  
Model Elite 7300W  
 
Before Using the Monitor  
INTRODUCTION  
Thank you for purchasing the Omron® Elite 7300W IntelliSense®  
Womens Advanced Automatic Blood Pressure Monitor.  
Fill in for future reference.  
DATE PURCHASED: __________________  
SERIAL NUMBER: ____________________  
Staple your purchase receipt here  
Your new digital blood pressure monitor uses the oscillometric method of  
blood pressure measurement. This means the monitor detects your  
bloods movement through your brachial artery and converts the  
movements into a digital reading. An oscillometric monitor does not need  
a stethoscope so the monitor is simple to use.  
The Elite 7300W comes with the following components:  
• Monitor  
• 4 “AAA” Batteries  
• Standard Arm Cuff  
• Stylish Zipper Case  
• Large Arm Cuff  
• Instruction Manual printed in English and Spanish  
• Quick Guide • Warranty Card • Cuff Guide  
The Elite 7300W IntelliSense® Womens Advanced Automatic Blood  
Pressure Monitor is intended for home use.  
While the Omron Elite 7300W is designed for women, it has also been  
clinically proven accurate for all adults, regardless of gender. So you can  
be assured that this product can be used by men and women.  
SAVE THESE INSTRUCTIONS  
3
 
SAFETY INFORMATION  
To assure the correct use of the product basic safety measures should  
always be followed including the warnings and cautions listed in this  
instruction manual.  
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL  
Indicates a potentially hazardous situation  
which, if not avoided, could result in death or  
serious injury.  
WARNING  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor or  
moderate injury to the user or patient or  
damage to the equipment or other property.  
CAUTION  
OPERATING THE DEVICE  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may  
be dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
If battery fluid should get in your eyes, immediately rinse with plenty  
of clean water. Contact a physician immediately.  
People with severe blood flow problems, or blood disorders, should  
consult a doctor before using the unit. Cuff inflation can cause  
internal bleeding.  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
4
 
SAFETY INFORMATION  
OPERATING THE DEVICE (continued)  
This device is intended for use in measuring blood pressure and pulse  
rate in the adult population. Do not use this device on infants or  
persons who cannot express their intentions.  
Inflating to a higher pressure may result in bruising where the cuff is  
applied.  
Operate the device only as intended. Do not use the device for any  
other purpose.  
Dispose of the device, components and optional accessories according  
to applicable local regulations. Unlawful disposal may cause  
environmental pollution.  
Do not use a cellular phone near the device. It may result in an  
operational failure.  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage the unit.  
Use only 1.5V alkaline batteries with this device.  
Do not use other types of batteries. This may damage the unit.  
5
 
SAFETY INFORMATION  
CARE AND MAINTENANCE  
Do not subject the monitor to strong shocks, such as dropping the unit  
on the floor.  
Do not submerge the device or any of the components in water.  
Store the device and the components in a clean, safe location.  
Changes or modification not approved by Omron Healthcare will void  
the user warranty. Do not disassemble or attempt to repair the unit or  
components.  
6
 
BEFORE TAKING A MEASUREMENT  
To ensure a reliable reading follow these recommendations:  
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for  
30 minutes before taking a measurement. Rest for at least 15 minutes  
before taking the measurement.  
2. Stress raises blood pressure. Avoid taking measurements during  
stressful times.  
3. Measurements should be taken in a quiet place.  
4. Remove tight-fitting clothing from your arm.  
5. Sit in a chair with your feet flat on the floor. Rest your arm on  
a table so that the cuff is at the same level as your heart.  
6. Remain still and do not talk during the measurement.  
7. Keep a record of your blood pressure and pulse readings for your  
physician. A single measurement may not provide an accurate  
indication of your true blood pressure. You need to take and record  
several readings over a period of time. Try to measure your blood  
pressure at about the same time each day for consistency.  
8. Wait 2-3 minutes between measurements. The wait time allows the  
arteries to return to the condition prior to taking the blood pressure  
measurement. You may need to increase the wait time depending on  
your individual physiological characteristics.  
7
 
Operating Instructions  
KNOW YOUR UNIT  
Main Unit:  
Display  
Air Jack  
Date/Time Setting  
Button (  
)
Memory Button (  
)
Start/Stop Button  
Battery Compartment  
8
 
KNOW YOUR UNIT  
Components:  
Arm Cuffs  
Air Tube  
Air Tube  
Air Plug  
Air Plug  
(Connects to Air Jack)  
(Connects to Air Jack)  
Standard Arm Cuff  
Large Arm Cuff  
Four “AAA” Batteries  
Stylish Zipper Case  
QUICK GUIDE  
Thank you for purchasing the Omron¤ Elite 7300W IntelliSense¤  
Women Advanced Automatic Blood Pressure Monitor.  
s
INSTRUCTION MANUAL  
There are two cuffs included in this unit, standard size and large size.  
This sheet simply explains how to choose the correct size cuff with Cuff  
Guide. However, please read the instruction manual thoroughly before  
using the unit.  
1. Make a loop with your Cuff Guide.  
Women’s Advanced  
Automatic Blood Pressure Monitor  
with Two Cuffs  
Model Elite 7300W  
2. Fit the looped Cuff Guide on your upper  
arm.  
3. Cuff Guide shows your correct cuff.  
Use the cuff with same colored sticker.  
Use the Standard Cuff  
(9"-13")  
Use the Cuff Guide to get your  
upper arm size, then choose  
the right size cuff.  
Orange  
Purple  
Use the Large Cuff  
(13"-17")  
Use the Cuff Guide to get your  
upper arm size, then choose  
the right size cuff.  
5318770-0A  
Quick Guide  
Instruction Manual  
Cuff Guide  
9
 
UNIT DISPLAY  
Systolic Blood Pressure  
Diastolic Blood Pressure  
Heartbeat Symbol/  
Medication Symbol  
Pulse Display  
Hypertension Indicator  
Deflation Symbol  
Memory Symbol  
Date/Time Display  
Guest Symbol  
Average Value Symbol  
Low Battery Indicator  
Movement Error Symbol  
Irregular Heartbeat Symbol  
10  
 
DISPLAY SYMBOLS  
IRREGULAR HEARTBEAT SYMBOL (  
)
When the monitor detects an irregular rhythm two or more times during  
the measurement, the Irregular Heartbeat Symbol ( ) will appear on the  
display with the measurement values.  
Normal Heartbeat  
An irregular heartbeat rhythm is defined as  
Pulse  
a rhythm that is more than 25% slower or  
25% faster from the average rhythm  
detected while the monitor is measuring the  
systolic blood pressure and the diastolic  
blood pressure.  
Blood  
pressure  
Irregular Heartbeat  
Short Long  
Pulse  
If the Irregular Heartbeat Symbol (  
)
displays with your measurement results, we  
recommend you consult your physician.  
Follow the directions of your doctor.  
Blood  
pressure  
MOVEMENT ERROR SYMBOL (  
)
The Movement Error Symbol (  
) is displayed if you move your body  
during the measurement. Please remove the arm cuff, and wait 2-3  
minutes. Take another measurement.  
11  
 
DISPLAY SYMBOLS  
HEARTBEAT SYMBOL/HYPERTENSION INDICATOR (  
)
TAKING A MEASUREMENT  
The Heartbeat Symbol ( ) flashes on the display during the  
measurement. The Heartbeat Symbol ( ) flashes at every  
heartbeat.  
When the measurement is complete, the Heartbeat Symbol (  
)
flashes on the display with your blood pressure and pulse rate if the  
reading is above 135 for the Systolic Blood Pressure value and/or 85  
for the Diastolic Blood Pressure value.  
USING THE MEMORY FUNCTION  
The Heartbeat Symbol ( ) flashes when the blood pressure  
reading stored in the memory is above 135 for the Systolic Blood  
Pressure value and/or 85 for the Diastolic Blood Pressure value.  
AVERAGE VALUE SYMBOL (  
)
The Average Value Symbol ( ) is displayed when you press the  
Memory button ( ). The most recent average reading appears on the  
display screen.  
12  
 
DISPLAY SYMBOLS  
The American Heart Association recommends the following guideline for  
upper limit of normal for home blood pressure readings:  
AHA Home Guideline for Upper Limit of Normal BP  
Systolic Blood Pressure  
135 mmHg  
Diastolic Blood Pressure  
85 mmHg  
This is a general guideline because blood pressure depends on  
age and morbidity. The AHA recommends a lower home blood  
pressure goal for certain patients, including diabetic patients,  
pregnant women, and patients with renal failure1.  
The monitor is not intended to be a diagnostic device.  
WARNING  
Contact your physician for specific information about your blood  
pressure. Self-diagnosis and treatment using measured results may be  
dangerous. Follow the instructions of your physician or licensed  
healthcare provider.  
Omron Healthcare recommends you contact your physician if the  
Heartbeat Symbol ( ) flashes on the display with your measurement  
values.  
1American Heart Association Scientific Statement 2004  
13  
 
BATTERY INSTALLATION  
1. Press the indicator on the battery cover  
and slide the cover off in the direction of  
the arrow.  
Battery Cover  
2. Install 4 “AAA” size batteries so the +  
(positive) and – (negative) polarities match  
the polarities of the battery compartment as  
indicated.  
3. Replace the battery cover.  
14  
 
BATTERY INSTALLATION  
BATTERY REPLACEMENT  
Low Battery Indicator  
When the Low Battery Indicator appears on the display screen, turn the  
monitor off and remove all the batteries. Replace with four new batteries  
at the same time.  
WARNING  
If battery fluid should get in your eyes, immediately rinse with plenty  
of clean water. Contact a physician immediately.  
NOTES: • Turn the unit off before replacing the batteries. If the batteries  
are removed while the unit is still on, the date and time will  
be reset to that of the previous use. However, the  
measurement results are not deleted.  
• When the batteries are replaced, you may need to reset the  
date and time. If the year is flashing on the display screen,  
refer to “Setting the Date and Time”.  
• The supplied batteries may have a shorter life.  
CAUTION  
Dispose of the device, components and optional accessories  
according to applicable local regulations. Unlawful disposal may  
cause environmental pollution.  
15  
 
SETTING THE DATE AND TIME  
Set the monitor to the current date and time before taking a measurement  
for the first time. If the date and time are not set correctly, the  
measurement values stored in the memory and the average values may  
not be correct.  
The Blood Pressure Monitor automatically stores up to 84 individual  
measurements values with the dates and times.  
The monitor can also calculate an average reading based on the three  
most recent measurements taken within 10 minutes.  
NOTES: • If only two readings are stored in the memory for the  
10-minute period, the average is based on the two readings.  
• If one reading is stored in the memory for the 10-minute  
period, this reading is displayed as the average.  
1. TO START THE SETTING  
Press and hold the Date/Time Setting button  
(
) to adjust the date and time.  
The year flashes on the display.  
16  
 
SETTING THE DATE AND TIME  
2. SETTING THE YEAR  
The year can be set between 2008 and 2030.  
When the display reaches 2030, it will return to  
2008.  
Press the Memory button ( ) to advance by  
increments of one year.  
Press the Date/Time Setting button (  
to set the current year.  
)
The month flashes on the display.  
NOTE: Press and hold the Memory button ( ) to advance the date and  
time values faster.  
3. SETTING THE MONTH  
Press the Memory button ( ) to advance by increments of one month.  
Press the Date/Time Setting button (  
to set the current month.  
)
The day flashes on the display.  
17  
 
SETTING THE DATE AND TIME  
4. SETTING THE DAY  
Press the Memory button ( ) to advance by increments of one day.  
Press the Date/Time Setting button  
(
) to set the current day.  
The hour flashes on the display.  
5. SETTING THE HOUR  
The time is set using AM or PM.  
Press the Memory button ( ) to advance by increments of one hour.  
Press the Date/Time Setting button  
(
) to set the current hour.  
The minute flashes on the display.  
6. SETTING THE MINUTE  
Press the Memory button ( ) to advance by increments of one  
minute.  
Press the Date/Time Setting button ( ) to turn the monitor off.  
18  
 
SETTING THE DATE AND TIME  
RESETTING THE DATE AND TIME  
To adjust the date or time after it has been setup when you first use  
the unit.  
Start with the monitor in the off position.  
1. Press and hold the Date/Time Setting button ( ).  
The Medication Symbol ( ) No.1 and the current setting (on or  
oFF) will appear on the display.  
Press the Date/Time Setting button repeatedly until the year flashes on  
the display.  
2. Refer to “Setting the Date and Time”.  
The Medication Symbol ( ) No.1 and the current setting (on or  
oFF) will appear on the display, after the minute has been set.  
3. Press the START/STOP button to turn the monitor off.  
NOTE: If you need to change the Date and Time, always adjust the  
Date and Time setting before taking the next measurement.  
19  
 
SETTING THE MEDICATION REMINDER ALARM  
The Medication Reminder Alarm can be set to sound twice a day to alert  
the user to take a medication. The Medication Reminder Alarm can be  
set for either AM or PM alerts. Only set the Medication Reminder Alarm  
after the date and time has been set. The Medication Reminder Alarm is  
set to off at the time of purchase.  
NOTES: • Press the START/STOP button to stop the Medication  
Reminder Alarm.  
• The Medication Reminder Alarm will automatically stop  
sounding after one minute.  
• The Medication Reminder Alarm will not sound when the  
monitor is taking a measurement.  
1. TO START THE SETTING  
Press and hold the Date/Time Setting  
button ( ).  
The Medication Symbol ( ) No.1 and the  
oFF setting appear on the display.  
20  
 
SETTING THE MEDICATION REMINDER ALARM  
2. SETTING ON OR OFF  
Press the Memory button ( ) to select on.  
Press the Date/Time Setting button ( ).  
The hour flashes on the display.  
NOTE: Press the Memory button ( ) to  
alternate between on or oFF.  
3. SETTING THE HOUR  
The time is set using AM or PM.  
Press the Memory button ( ) to advance by increments of one hour.  
Press the Date/Time Setting button (  
to set the hour.  
)
The minute flashes on the display.  
21  
 
SETTING THE MEDICATION REMINDER ALARM  
4. SETTING THE MINUTE  
Press the Memory button ( ) to advance by increments of one  
minute.  
Press the Date/Time Setting button  
(
) to set the minute.  
The Medication Symbol ( ) No.2 and the  
oFF setting appears on the display.  
5. SETTING THE MEDICATION REMINDER ALARM 2  
Repeat steps from 2 to 4 to set the Medication  
Reminder Alarm 2.  
The year flashes on the display, after the  
Medication Reminder Alarm 2 has been set.  
22  
 
SETTING THE MEDICATION REMINDER ALARM  
6. TO TURN THE MONITOR OFF  
If the date and time are correct, press the START/STOP button to turn  
the monitor off.  
To change the date and time refer to “Resetting the Date and Time” on  
page 19.  
23  
 
APPLYING THE ARM CUFF  
CAUTION  
Read all of the information in the instruction manual and any other  
literature in the box before operating the unit.  
CAUTION  
This device is intended for use in measuring blood pressure and pulse  
rate in the adult population. Do not use this device on infants or  
persons who cannot express their intentions.  
USE CUFF GUIDE TO CHOOSE THE RIGHT CUFF  
There are two cuffs included in this unit, standard size and large size.  
Use the Cuff Guide to determine which size cuff is right for you, based  
on the circumference of your arm.  
1. Make a loop with your Cuff Guide.  
24  
 
APPLYING THE ARM CUFF  
2. Fit the looped Cuff Guide on your upper  
arm.  
3. Cuff Guide shows your correct cuff.  
Use the cuff with same colored sticker.  
Orange  
Purple  
Use the Standard Cuff  
Use the Large Cuff  
APPLYING THE CUFF ON THE LEFT ARM  
1. Make sure the air plug is securely inserted in the main unit.  
25  
 
APPLYING THE ARM CUFF  
2. Remove tight-fitting clothing from your upper left arm.  
3. Apply the cuff to your left upper arm so the blue arrow is centered on  
the inside of your arm and aligned with your middle finger. The air  
tube runs down the inside of your arm. The bottom of the cuff should  
be approximately 1/2" above your elbow.  
1/2 inch (1 - 2 cm)  
Blue Arrow  
Air Tube  
4. Wrap the cuff firmly in place around  
your arm using the closure strip.  
26  
 
APPLYING THE ARM CUFF  
APPLYING THE CUFF ON THE RIGHT ARM  
When taking a measurement using the right arm use this instruction  
for Step 3 on page 26.  
Apply the cuff to your right upper arm so the blue arrow and the air tube  
runs along the inside of your elbow. The bottom of the cuff should be  
approximately 1/2'' above your elbow.  
NOTE: Be careful not to rest your arm on the air tube. This will restrict  
the flow of air to the cuff.  
27  
 
TAKING A MEASUREMENT  
1. Sit in a chair with your feet flat on the floor. Place your left arm on a  
table so the cuff is level with your heart.  
2. Press the START/STOP button.  
All symbols appear on the display.  
The cuff starts to inflate automatically. As the cuff inflates, the monitor  
automatically determines your ideal inflation level.  
This monitor detects your blood pressure and pulse rate during  
inflation. The Heartbeat Symbol ( ) flashes at every heartbeat. Do  
not move your arm and remain still until the entire measurement  
process is completed.  
NOTE: To stop the inflation or measurement, press the START/STOP  
button. The monitor will stop inflating, start deflating and will  
turn off.  
28  
 
TAKING A MEASUREMENT  
3. When the measurement is complete, the arm cuff  
completely deflates. Your blood pressure and  
pulse rate are displayed.  
4. Press the START/STOP button to turn the  
monitor off.  
NOTE: The monitor will automatically turn off  
after two minutes.  
29  
 
TAKING A MEASUREMENT  
USING THE GUEST MODE  
The monitor is designed to take measurements and store the  
measurement values in the memory for one person. The monitor can also  
be used to take a single measurement for other persons using the GUEST  
Mode. Measurements taken using the Guest Mode are not stored in the  
memory.  
1. Press and hold the START/STOP button for 3  
seconds.  
The Guest Symbol (  
display.  
) appears on the  
2. Release the START/STOP button.  
The cuff starts to inflate automatically.  
NOTE: To stop the inflation, press the START/STOP button. The  
monitor will stop inflating, start deflation and turn off.  
3. Inflation stops and the measurement is started. When the measurement  
is completed, your blood pressure and pulse rate appear on the display.  
30  
 
USING THE MEMORY FUNCTION  
Every time you complete a measurement the monitor stores the blood  
pressure and pulse rate in the memory.  
The monitor automatically stores up to 84 sets of measurement values  
(blood pressure and pulse rate). When 84 sets of measurement values are  
stored, the oldest record is deleted to save the most recent values.  
Measurements taken using the GUEST Mode are not stored in the  
memory.  
AVERAGING FUNCTION  
The monitor calculates the average reading based on the three most  
recent sets of measurement values taken within 10 minutes.  
NOTE: If two sets of measurement values are stored in the memory for  
the 10 minutes period, the average is based on the two sets of  
measurement values. If one set of measurement values is stored,  
this is displayed as the average.  
TO DISPLAY THE MEASUREMENT VALUES  
1. Press the Memory button ( ).  
The Average Symbol ( ) appears on the display when the average  
reading is shown.  
31  
 
USING THE MEMORY FUNCTION  
2. Press the Memory button ( ) to display the most recent set of  
measurement values on the screen. The values are displayed from the  
most recent to the oldest.  
NOTE: The date and time are  
alternately displayed with the  
measurement values.  
Press the Memory button ( ) to  
display the next set of values.  
Press and hold the Memory button  
(
) to display the values faster.  
Alternating display  
3. Press the START/STOP button to turn the power off.  
32  
 
USING THE MEMORY FUNCTION  
TO DELETE ALL VALUES STORED IN THE MEMORY  
You cannot partially delete values stored in the memory.  
1. Press the Memory button ( ) to turn the monitor on.  
2. Press the Memory button (  
again.  
)
While holding it down, press  
the START/STOP button  
together for more than 5  
seconds.  
3. Press the START/STOP button to turn the monitor off.  
NOTE: The monitor will automatically turn off after two minutes.  
33  
 
Care and Maintenance  
CARE AND MAINTENANCE  
To keep your digital blood pressure monitor in the best condition and  
protect the unit from damage, follow the directions listed below:  
Keep the monitor in the Stylish Zipper  
Case when not in use.  
Do not forcefully bend the arm cuff or air tube. Do not fold tightly.  
Clean the monitor with a soft dry cloth. Do not use any abrasive  
or volatile cleaners. Do not attempt to clean the cuff.  
CAUTION  
Do not submerge the device or any of the components in water.  
Do not subject the monitor to extreme hot or cold temperatures,  
humidity or direct sunlight.  
CAUTION  
Store the device and the components in a clean, safe location.  
CAUTION  
Do not subject the monitor to strong shocks, such as dropping the  
unit on the floor.  
Remove the batteries if the unit will not be used for three months or  
longer. Always replace all the batteries with new ones at the same time.  
34  
 
CARE AND MAINTENANCE  
Use the unit consistent with the instruction provided in this manual.  
CAUTION  
Changes or modification not approved by Omron Healthcare will  
void the user warranty. Do not disassemble or attempt to repair the  
unit or components.  
CAUTION  
Use only Omron authorized parts and accessories. Parts and  
accessories not approved for use with the device may damage  
the unit.  
35  
 
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
ERROR INDICATORS  
SYMBOL  
CAUSE  
CORRECTION  
Remove the arm cuff. Read,  
“Taking a Measurement”.  
Take another measurement.  
Cuff over-inflated  
Monitor could not  
detect pulse wave.  
Take another measurement and  
remain still until the  
measurement is complete.  
Air plug is not  
connected.  
Contact your OMRON  
distributor or Customer Services  
as mentioned on the package.  
A malfunction has  
occured.  
Replace the four batteries.  
Refer to “Battery Installation.”  
Batteries are worn  
36  
 
ERROR INDICATORS AND TROUBLESHOOTING TIPS  
TROUBLESHOOTING TIPS  
PROBLEM  
CAUSES AND SOLUTIONS  
No power.  
Replace all four batteries with new  
ones.  
No display appears on the unit. Check the battery installation  
for proper placement of the  
battery polarities.  
Blood pressure varies constantly.  
Many factors including stress, time  
of day, and how you wrap the cuff,  
may affect your blood pressure.  
Review the sections “Before Taking  
Measurement values appear  
too high or too low.  
a Measurement” and “Taking a  
Measurement”.  
37  
 
FCC STATEMENT  
NOTE:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class B  
digital device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. The product generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular  
installation. If the product does cause harmful interference to radio or television  
reception, which can be determined by turning the product on and off, the  
user is encouraged to try to correct the interference by one or more of the  
following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the product and the receiver.  
• Connect the product into an outlet on a circuit different from that to which  
the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio noise  
emissions from digital apparatus as set out in the interference-causing equipment  
standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of  
Communications.  
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables  
aux appareils numériques de Clase B prescrites dans la norme sur le materiel  
brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister des  
communications.  
Changes or modifications not expressly approved by the party responsible for  
compliance could void the users authority to operate the equipment.  
38  
 
WARRANTY  
Your Omron® Elite 7300W IntelliSense® Womens Advanced Automatic Blood  
Pressure Monitor, excluding the arm cuffs, is warranted to be free from defects in  
materials and workmanship appearing within 5 years from the date of purchase,  
when used in accordance with the instructions provided with the monitor. The arm  
cuffs are warranted to be free from defects in materials and workmanship  
appearing within one year from the date of purchase when the monitor is used in  
accordance with the instructions provided with the monitor. The above warranties  
extend only to the original retail purchaser.  
We will, at our option, repair or replace without charge any monitor or arm cuff  
covered by the above warranties. Repair or replacement is our only responsibility  
and your only remedy under the above warranties.  
To obtain warranty service contact Omron Healthcare for the address of the repair  
location. Shipping instructions and repair information is available by calling  
Enclose the Proof of Purchase. Include $5.00 for the return shipping and handling.  
Include a letter, with your name, address, phone number, and description of the  
specific problem. Pack the product carefully to prevent damage in transit. Because  
of possible loss in transit, we recommend insuring the product with return receipt  
requested.  
ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO  
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS  
FOR PARTICULAR PURPOSE, ARE LIMITED TO THE DURATION OF  
THE APPLICABLE WRITTEN WARRANTY ABOVE. Some states do not  
allow limitations on how long an implied warranty lasts, so the above limitation may  
not apply to you.  
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER  
INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES  
OR DAMAGES. Some states do not allow the exclusion or limitation of incidental  
or consequential damages, so the above exclusions may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights  
which may vary from state to state.  
FOR CUSTOMER SERVICE  
Visit our web site at:  
Call toll free:  
1-800-634-4350  
39  
 
SPECIFICATIONS  
Model:  
Display:  
Elite 7300W  
LCD Digital Display  
Measurement Range:  
Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.  
Accuracy/Calibration: Pressure: 3mmHg or 2% of reading  
Pulse: 5% of reading  
Inflation:  
Automatic by electric pump  
Deflation:  
Rapid Air Release:  
Pressure Detection:  
Automatic rapid deflation pressure  
Automatic exhaust valve  
Electrostatic capacity semi-conductor pressure sensor  
Measurement Method: Oscillometric method  
Pulse Wave Detection: Capacitance type pressure sensor  
Power Source:  
Battery Life:  
4 “AAA” batteries (1.5V Alkaline)  
Approximately 300 uses when used 3 times a day with new  
alkaline batteries when inflated to 170mmHg at 73ºF  
(23ºC).  
Operating Temperature 50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH  
/Humidity:  
Storage Temperature  
/Humidity/Air Pressure: /700 - 1060 hPa  
Main Unit Weight: Approximately 8 1/2 oz. (240 g)  
not including batteries  
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH  
Main Unit Dimensions: Approximately 6 3/16" (l) × 2 15/16" (w) × 1 7/32" (h)  
(157 mm × 74 mm × 30.6 mm)  
Cuff Size:  
Standard Cuff  
Approximately 5 3/4" (w) × 17 1/2" (l)  
(146 mm × 446 mm)  
Cuff tube 23 5/8" (l) (600 mm)  
Large Cuff  
Approximately 6 7/8" (w) × 25 11/16" (l)  
(174 mm × 652 mm)  
Cuff tube 35 7/16" (l) (900 mm)  
Standard Cuff fits arm circumferences 9" to 13"  
(220 mm to 320 mm)  
Cuff Circumference:  
Large Cuff fits arm circumferences 13" to 17"  
(320 mm to 420 mm)  
40  
 
SPECIFICATIONS  
Memory:  
Contents:  
Up to 84 readings  
Main Unit, Standard and Large Arm Cuffs,  
Instruction Manual, 4 “AAA” batteries,  
Stylish Zipper Case, Quick Guide, Warranty Card and  
Cuff Guide  
UPC Code:  
0 73796 73000 0  
NOTE: These specifications are subject to change without notice.  
41  
 
Manufactured by OMRON HEALTHCARE  
Made in China  
Distributed by:  
OMRON HEALTHCARE, INC.  
1200 Lakeside Drive  
Bannockburn, Illinois 60015  
Copyright © 2007 Omron Healthcare, Inc.  
 

Miele Oven H4680B User Manual
Miele Vacuum Cleaner S 4212 S 4782 User Manual
MTD Lawn Mower OEM 190 118 User Manual
MTD Ventilation Hood ERV 350 User Manual
Nextar GPS Receiver X3E User Manual
Nilfisk Advance America Lawn Sweeper 56316025 R32 C User Manual
Palsonic Flat Panel Television 6820PF User Manual
Panasonic Answering Machine KX TG242SK User Manual
Panasonic Cordless Telephone KX TG6451BX User Manual
Panasonic Digital Camera AK HC900P User Manual