READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
Bathroom Exhaust
Fan/Fluorescent
Light Combination
9"
9"
Wiring
Knockouts
6"
Housing
Slots
MODEL: 8663RF
Suitable for use in shower or tub enclosure when used
with GFCI protected branch circuit.
Scroll
Power/Blower
Unit
The exhaust fan consists of the housing, power unit/blower
assembly (motor, wheel, mounting plate,) grille/lens assembly,
reflector/lamp plug assembly (lamps not furnished,) and duct collar.
• WARNING: To reduce the risk of shock, do not use this fan with
any solid-state speed control device.
• Acceptable for use over tub or shower when installed on a GFCI
protected branch circuit.
• Not for use in kitchens.
Do not install in a ceiling insulated to a value greater than R-40.
Wing Nut
Reflector
Assembly
IMPORTANT SAFETY INSTRUCTIONS
Mounting
Springs (2)
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at Service Panel
and lock Service Panel to prevent power from being switched on
accidentally.
Grille/Lens
Assembly
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the
service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
1
/
8
14 " DIA.
FIGURE 1
INSTALLATION INSTRUCTIONS
FOR BEST RESULTS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction.
B. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
When installing the Exhaust Fan/Light in a new construction site,
install housing during the rough-in construction of the building. The
blower unit, reflector and grille should be installed after the finished
ceiling is in place.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For
best fan performance, make duct run as short as possible and use
minimum number of elbows.
3. Use optional NuTone ducting accessories as needed.
WIRING
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or
shower.
Plan to run 120vAC house wiring (with ground) from power source,
through wall switch, to junction box in housing. For separate control of
fan and light use an optional NuTone switch.
IMPORTANT: Use wire suitable for 90oC.
COMPLETING INSTALLATION
11-1/2"
1. Insert lamp plug into junction box receptacle and secure reflector
assembly to motor frame with wing nut provided.
2. Insert lamp (26 watt compact fluorescent - NEMA Type
CFQ26W/G24D) into the socket.
5-3/4"
NOTE: Lamp must be purchased separately.
3. Insert the grille assembly's mounting springs into the slots on both
sides of the housing by squeezing the springs together.
4. Press grille assembly firmly into place against the ceiling.
2"
CLEANING AND RELAMPING
1. Pull grille assembly away from ceiling.
2. Squeezing the grille assembly's mounting springs together,
remove grille assembly from housing to expose socket for
relamping.
4"
9-1/8"-10"
3. Clean grille and lens of assembly using a mild soap and water
solution.
4. Replace grille assembly flat against ceiling after cleaning or
relamping.
Joist
FIGURE 6
INSTALLATION IN EXISTING CONSTRUCTION
PLANNING
Review “INSTALLATION IN A NEW CONSTRUCTION SITE” and
follow all instructions which apply to your installation.
LOCATION: Locate fan between ceiling joists.
WIRING AND DUCTING: Plan ducting and wiring BEFORE
proceeding with installation. Refer to Figures 4 and 5 for wiring and
Figure 3 for ducting.
4" Flexible
Duct
CAUTION: Check area above planned location to be sure that:
1. Ducting can be installed or that area is sufficient for proper
venting.
2. Wiring can be run to the planned location.
3. No wiring or other obstruction might interfere with installation.
INSTALLATION
120vAC
House Wiring
1. The fan must be mounted between ceiling joists. Decide where
you want to locate the fan, and then determine where the nearest
joists are.
2. Locate the joists. Drill a starter hole in the ceiling between the
joists.
Duct
Collar
3. To exactly locate the edge of joist, saw a line from hole to joist.
4. Refer to page 1. Remove power/blower unit from housing.
5. Use the housing pan as a template to mark cutout: place pan
centered between joist and trace around pan.
6. Make cutout along outside of marked line.
7. Refer to Figure 6. Install 2 x 4 cleats to both ceiling joists. In
some cases it may be necessary to use more than a single cleat
on one side. The distance between cleats must be at least 91/8"
but not more than 10".
Mounting
Holes
Wiring
Knockout
Bend
Mounting
Tabs
Flush To
Side of
Housing
8. Remove side wiring knockout and insert and secure an approved
box connector into the wiring entrance hole.
9. Use pliers to bend both mounting tabs as flush as possible to the
side of the housing.
FIGURE 7
10. Install duct collar.
11. String wiring through box connector and connect 4" flexible duct
to duct collar.
12. Carefully push ductwork and wiring back into cutout. Place
housing into cutout.
13. Use wood screws to secure housing to cleats through four holes
in housing's pan. make sure pan is flush to finished ceiling.
14. Install Power/Blower Unit and complete installation.
3
One Year Limited Warranty
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE:To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation
Builder or Installer
Model No. and Product Description
IFYOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
Rev. 03/2001
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 04/2001, Part No. 87588
Product specifications subject to change without notice.
EFFECTIVE
DATE
PRODUCT
GROUP
MODEL NUMBER
8663RF
PARTS LIST
DECEMBER
1997
FAN
11
9
7
8
5
5
6
16
17
2
4
15
13
3
3
12
1
4
14
18
CURRENT
REPLACEMENT
PART NO.
ORIGINAL
PART NO.
MODEL USED ON
REF.
PART DESCRIPTION
1
2
87587
86933
32787
32788
51919
63007
89248
85936
85976
16133
30652
82304
10034
85970
89539
85937
57000
44388
POWER UNIT ASSEMBLY
MOTOR
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
8663RF
87587-000
86933-000
32787-000
32788-000
51919-000
51919-000
89248-000
85936-000
85976-000
16133-000
30652-000
82304-000
10034-000
85970-000
89539-000
85937-000
57000-000
44388-000
3
MOTOR ISOLATION MOUNT
GROUND CLIP
4
5
BLOWER WHEEL
PUSH NUT
6
7
REFLECTOR
8
LAMPHOLDER BRACKET
LAMPHOLDER, BALLAST&PLUGASSEMBLY
WING NUT
9
10
11
12
13
14
15
16
17
18
DUCT ADAPTER ASSEMBLY
RECEPTACLE - WHITE
RECEPTACLE - BLACK
GRILLE ASSEMBLY
GRILLE
LENS
GRILLE SPRING (1)
HANGER BAR (1)
NuTone
Attn: Parts Department
®
4820 Red Bank Road
Cincinnati, OH 45227-1599
Phone: (513) 527-5426
Fax: (513) 527-5173
NOTE: Always order by
current part number
8663RF I.I.
|