Milan Technology Cable Box MIL C1111 User Manual

MIL-C1111  
Re g u la t o r y A p p r o v a ls  
FCC Class A  
UL 1950  
CSA C22.2 No. 950  
EN60950  
MIL-C1 1 1 1  
Co a x to Ba se -T (UTP)  
Me d ia Co n ve rte r  
In sta lla tio n Gu id e  
CE  
•– EN55022 Class B  
•– EN50082-1  
Ca n a d ia n EM I N o t ice  
This Class A digital apparatus meets all the requirements of the Canadian  
Interference-Causing Equipment Regulations.  
Cet appareil numérique de la classe A respecte toutes les exigences  
du Règlement sur le matériel brouilleur du Canada.  
Eu r o p e a n N o t ice  
Products with the CE Marking comply with both the EMC Directive (89/336/EEC)  
and the Low Voltage Directive (73/23/EEC) issued by the commission of the European  
Community. Compliance with these directives implies conformity to the following  
European Norms:  
500 mA  
EN55022 (CISPR 22) - Radio Frequency Interference  
EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity  
EN60950 (IEC950) - Product Safety  
MIL-C1111  
Fiv e Ye a r W a r r a n t y  
Ethernet  
MiLAN Technology warrants to the original consumer or purchaser that each of its  
products, and all components thereof, will be free from defects in material and/or  
workmanship for a period of five years from the original factory date. Any warranty  
hereunder is extended to the original consumer or purchaser and is not assignable.  
MiLAN Technology makes no express or implied warranties including, but not limited to,  
any implied warranty of merchantability or tness for a particular purpose, except as  
expressly set forth in this warranty. In no event shall MiLAN Technology be liable for  
incidental or consequential damages, costs, or expenses arising out of or in connection  
with the performance of the product delivered hereunder. MiLAN Technology will in  
no case cover damages arising out of the product being used in a negligent fashion or  
manner.  
COAX to 10BASE-T  
IEEE 802.3 Compliant  
Tr a d e m a r k s  
© 2000 MiLAN, the MiLAN logo, and MiLAN Technology are either trademarks or registered trademarks of  
Digi International, Inc. in the United States and/or other countries. All other trademarks are the property of  
their respective holders.  
To Co n t a ct M iLA N Te ch n o lo g y  
For prompt response when calling for service information, have the following information ready:  
Product serial number and rev; date of purchase; vendor or place of purchase.  
You can reach MiLAN Technology technical support at: support@milan.com  
Telephone: +1.408.744.2751 Fax: +1.408.744.2771  
POWER  
TX ACTIVE  
TX LINK  
COAX ACTIVE  
COAX ENABLE  
MiLAN Technology 1299 Orleans Drive, Sunnyvale, CA 94089-1138 United States of America  
Telephone: +1.408.744.2775 Fax: +1.408.744.2793  
Coax  
UTP  
info@milan.com  
© Copyright 2000 MiLAN Technology  
Printed in the U.S.A.  
In sta lla tio n  
LEDs  
Follow the steps given below to install the MIL-C1111:  
1. Attach a UTP cable from network to MIL-C1111s RJ-45 port.  
2. Attach a T-type BNC connector from network cabling to the BNC  
connector.  
3. Plug the power adapter into an AC outlet and connect the power  
adapter cord to the unit.  
EMI Note: Use shielded UTP (CAT 5) cabling for CISPR 22 classB.  
Co n g u ra tio n -Te rm in a tio n Sw itch  
Next to the coax cable connector, there are DIP switches that  
control the 50 Ohm internal resistor. Both switches are shipped in  
the “up” position (default, no termination).  
TP ACT: Amber, indicates a packet activity on the 10BASE-T net-  
work.  
COAX ACT: Amber, indicates a packet activity on the 10BASE2  
network.  
TP LINK: Green, there is a good link on the 10BASE-T network.  
COAX ENAB: Green, coax connection is established.  
Ca b lin g O p tio n s: MDI-X/ MDI Sw itch  
The MDI-X/MDI switch is located on the side of the unit. This  
switch enables a quick configuration of the 10BASE-T port.  
Cables used when the switch is in the MDI-X position:  
For a hub or repeater, use a swap cable (pins are connected 1 to 3,  
2 to 6, 3 to 1, 6 to 2).  
Co n g u ra tio n O p tio n s  
1. If the MIL-C1111 is connected to the end of a multinode segment  
For a workstation or PC, use a straight-through cable (pins are  
connected 1 to 1, 2 to 2, 3 to 3, 6 to 6).  
without a T-connector and terminator, enable 50 Ohm resistor by  
Setting switch 1 up”  
Setting switch 2 down”.  
Cables used when the switch is in the MDI position:  
For a hub or repeater, use a straight-through cable (pins are con-  
nected 1 to 1, 2 to 2, 3 to 3, 6 to 6.  
2. If the MIL-C1111 is connected to a single-nod without a T-type  
connector and terminator on a coax cable of less than one meters  
length:  
For a workstation or PC, use a swap cable (pins are connected 1 to  
3, 2 to 6, 3 to 1, 6 to 2.  
Set both switches in the “down” position.  
RJ-4 5 Sp e cifica tio n s  
Note: For this configuration, you do not need a 50 Ohm  
terminator on the coax segment of the MIL-C1111s BNC  
connector.  
4
5
3
6
MDI  
Pin 1=TX+  
Pin 2=TX-  
Pin 3=RX+  
Pin 6=RX-  
7
2
8
MDI-X  
1
Pin 1=RX+  
Pin 2=RX-  
Pin 3=TX+  
Pin 6=TX-  
©Copyright 2000 MiLAN Technology PN 90000213 Printed in the USA  
 

Miele Clothes Dryer T1526 User Manual
MTD Lawn Mower 110 500 User Manual
Multiquip Saw TP7X User Manual
Nady Systems Portable Speaker PCS 15 User Manual
NetComm Network Router NB1200 User Manual
NETGEAR Computer Drive Pioneer Edition User Manual
Nintendo Video Games 45496742355 User Manual
Onkyo Stereo System TX DS989 User Manual
Oregon Chainsaw 91VG User Manual
Panasonic MP3 Player CQ RX101N User Manual