K00133/K00134 MAC-7 and MAC-8
HEADMASTER KITS
Installation Instructions
IMPORTANT - Refrigerant line lengths must not exceed 50 feet.
1. Lubricate the female fittings with refrigerant oil and install the assembly of the quick-connect fittings on the MAC-7
or MAC-8 condensing unit.
2. The metal enclosure attaches to the MAC-7 or MAC-8 condensing unit with three screws from the unit, two screws on
top and one screw at the bottom.
3. The remote tubing line set attaches to the male fittings provided on the headmaster kit. Refrigerant oil must be used
to lubricate the fittings.
4. Leak check all joints.
5. Place the four labels, 8136193, included, as follows: two on the ice machine (one by each serial plate), one, as shown
below, and one at the discretion of the installer.
6. ATTENTION INSTALLER: Add the following refrigerant at the time of installation:
Q-0600 Series - add four (4) pounds
Q-0800 Series - add four (4) pounds
Q-1000 Series - add two (2) pounds
Q-1300 Series - Add nothing
Manitowoc Ice, Inc.
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879
Web Site - www.manitowocice.com
8010113
Rev. 06/28/01
|
Krell Industries Stereo Amplifier PAM 5 User Manual
LevelOne Switch KVM 0213 User Manual
Lexmark All in One Printer X644E User Manual
LG Electronics Clothes Dryer DLEX3570V User Manual
Lightolier Indoor Furnishings 1113CFL User Manual
Logitech Car Speaker Z506 User Manual
LOREX Technology VCR SG7965 User Manual
Maha Energy Video Gaming Accessories IW4 WB WBV User Manual
Makita Home Safety Product ML18 User Manual
Metabo Welding System E 130 User Manual